gbfisedeesfritpt

I/A/mA

Items under this category

photo_335

EM-M11A MULTISCALE GALVANIC SIGNAL ISOLATOR AND CONDITIONER

  • Three way isolated
  • Multiple operating ranges
  • Two frequency ranges
  • Dip-switch settable
  • Isolation up to 1000 V
  • Adjustable zero and gain
  • Short circuit protected
  • Rail mountable
photo_430

EM-M14 LOOP POWERED 4...20 mA GALVANIC ISOLATOR

  • No supply required
  • Operation range 0...25 mA
  • Isolation up to 2000 V
  • Low voltage drop
  • Over current protected
  • Over voltage protected
  • Incorrect polarity protected
  • Wide input voltage range
  • Rail mountable
photo_347

EM-M24 MULTISCALE GALVANIC ISOLATOR ALSO FOR BIPOLAR SIGNALS

  • Three way isolated
  • Multiple operating ranges
  • Also for bibolar signals
  • DIP-switch settable ranges
  • Two frequency ranges
  • Adjustable zero and gain
  • Isolation voltage 1000 V
  • Short-circuit protected
  • Rail mountable
photo_441

EM-M41 INPUT ISOLATOR FOR PLCs AND CONTROL SYSTEMS, FROM I TO I

  • Wide supply range
  • Isolation voltage 1500 V
  • 12-bit linearity
  • Small size
  • Single- and dual-ch units
  • Over current protected
  • Over voltage protected
  • Easy to connect
  • Rail mountable
photo_357

EM-M43 INPUT ISOLATORS FOR PLCs AND CONTROL SYSTEMS, FROM I TO U

  • Wide supply range
  • Isolation voltage 1500 V
  • 12 bit linearity
  • Small size
  • Single- and dual-ch units
  • Over current protected
  • Easy to connect
  • Rail mountable
photo_357

EM-M43-2 INPUT ISOLATORS FOR PLCs AND CONTROL SYSTEMS, FROM I TO U

  • 2 Channel type
  • Cost effective
  • Wide supply range
  • Isolation voltage 1500 V
  • 12 bit linearity
  • Small size
  • Single- and dual-ch units
  • Over current protected
  • Easy to connect
  • Rail mountable
photo_445

EM-M69 CURRENT MEASURE UNIT 50A dc/ac

  • Wide frequency range
  • True RMS measurement
  • Also for thyristor power controller and inverter current measurement
  • Dip switch settable
  • 50A RMS (150A peak)
  • mA and V output
  • Gain and zero adjustment
  • Over voltage protected
  • Reversed polarity protected
  • Easy to connect
  • Rail mounting base available
photo_446

EM-M69-iso CURRENT MEASURE UNIT 50A dc/ac

  • Wide frequency range
  • True RMS measurement
  • Galvanic supply isolation
  • Also for thyristor power controller
  • and inverter current measurement
  • Dip switch settable
  • 50A RMS (150A peak)
  • mA and V output
  • Gain and zero adjustment
  • Over voltage protected
  • Reversed polarity protected