EM-324C DC-Motor Controller

EM-324 is a full bridge DC-motor starter. It is designed to work with DC-motor in applications where some special functions are needed. Starter has adjustable acceleration and deceleration ramps, which make possible the smooth starts and stops. Adjustable current limit protects motor against overcurrent and it can also be used as an end-stop. This device has also two settable speeds, which are useful in positioning applications. Control inputs FW and BW start the forward and backward run. STOP is for the motor shutdown but there are also available individual limit inputs for FW and BW directions. SPEED-2 input activates preset speed-2, but it can also be used as input for analog speed control signal 0-5V. FAULT terminal has at the same time input and output function, the pin is normally high, but is pulled down in overheat and conditionally also in current trip situation. If FAULT-line is pulled down externally it will cause a stop and prevent the new start. For example, it is possible to link fault pins of several units together and achieve a synchronous stop.

There are two selectable control modes, continuous and impulse. In continuous mode the motor runs as long as the control is active. In impulse mode a short command starts the motor, and only a new impulse will change the status. There is also few special settings start-kick and auto reverse. The card has selectable input logics. Inputs are divided in two groups, control and limit -inputs. Groups can be individually set for NPN or PNP logic. The parameters are set with EM-236 interface unit. Operation of the controller and some of its functional values can also be monitored with EM-236 interface unit.

.


TECHNICAL DATA EM 324C (PCB Version v2)
Supply voltage10-35V
Overvoltage shutdown38V
Motor current cont. max4A (Ta)
Motor current peak8A (10s)
Voltage drop0.3V at 4A
PWM frequency2kHz or 16kHz
Start ramp0..2.5 s, settable
Stop ramp0..2.5 s, settable
Current limit0.1-8A, settable
Control range0-5V or 0-10V, adjustable
Output range0-5V ... 0-33V, settable
Control input impedances100kohm
Fault outputNPN max. 50mA
with SW1 can be connected to 2.2k pull-up resistor
Connectors (supply and power)1.5mm²
Dimensions72x20x17mm
Dimensions in rail base90x23x48mm
Connectors (control)1mm²
EMCEN-50081-2 & EN-50082-2 (industrial)
Weight30g
Operating temp. (Ta)-40...70°C

Product files

EN_em-324C.pdf (191,19 KB)
EN_em-324C_app.pdf (76,70 KB)
EN_em-Rail_bases.pdf (2.833,53 KB)
Stock: 892 pcs.
34,00 €
VAT 0%

AAA - credit rating

ISO-certified suppliers and subcontractors

100% Finnish production chain

Device design, programming, and laboratory testing

Short delivery time

Back to top