EM-M22 I/A/mA Converter

Key Features

  • True RMS converter for AC current measurement
  • Designed for use with standard current transformers
  • Selectable 1 A and 5 A current-transformer input ranges
  • Suitable for sinusoidal and non-sinusoidal current waveforms
  • Converts the measured AC current into a 4–20 mA signal
  • Loop-powered operation without a separate auxiliary supply
  • Optional 1–5 V output using an external conversion resistor
  • Measuring-frequency range from 45 Hz to 1 kHz
  • Protection against incorrect connections and voltage transients

Overview

EM-M22 is a True RMS signal converter designed for AC current measurement using a current transformer. It accepts the standard 1 A and 5 A secondary-current ranges commonly used in current-transformer applications.

The measured AC current is converted into a standard 4–20 mA process signal. The output circuit is powered from the current loop, so no separate auxiliary supply is required.

Read more Show less

True RMS Current Measurement

The EM-M22 measures the effective RMS value of the current-transformer secondary signal. True RMS measurement enables the converter to process both sinusoidal and non-sinusoidal current waveforms within the specified operating limits.

The supported measuring-frequency range is 45 Hz to 1 kHz.

Current-Transformer Inputs

Two measuring ranges are provided for standard current-transformer secondary currents:

  • 0–1 A AC RMS
  • 0–5 A AC RMS

The 1 A range has a specified input impedance of 0.27 Ω. The 5 A range has a specified input impedance of 0.05 Ω.

Current-Loop Output

The measured current is converted into a proportional 4–20 mA output signal. The output loop operates from a 12–32 VDC supply and provides the operating power required by the converter.

With a 24 VDC loop supply, the specified maximum loop resistance is 700 Ω.

1–5 V Output

The 4–20 mA output can also be converted into a 1–5 V signal by connecting a suitable resistor according to the connection diagram.

A 250 Ω conversion resistor produces a nominal voltage of 1 V at 4 mA and 5 V at 20 mA.

Protection

The EM-M22 includes protection against incorrect connections and voltage transients.


Technical Data EM-M22

Output-loop supply voltage 12–32 VDC
Measurement principle True RMS
AC current range 1 0–5 A RMS
Peak current, 5 A range 20 A peak
Input impedance, 5 A range 0.05 Ω
AC current range 2 0–1 A RMS
Peak current, 1 A range 4 A peak
Input impedance, 1 A range 0.27 Ω
Current output 4–20 mA
Optional voltage output 1–5 V using a conversion resistor
Linearity error < 0.5% with a sinusoidal input
Thermal drift < 200 ppm/°C
Settling time 0.3 s
Measuring-frequency range 45–1000 Hz
Maximum loop resistance 700 Ω with a 24 VDC loop supply
Operating ambient temperature 0 … +50 °C

Product files

EN_em-m22.pdf (47,38 KB)
Stock: 50+ pcs.
67,00 €
VAT 0%

Ordering larger quantities +100pcs.

For volume discounts pls. see the Contact Info for Electromen distributors. If you didn´t find your country distributor then ask direct offer from office@electromen.com