EM-A1 Symmetric Control

Key Features

  • Compact option card for compatible Electromen motor controllers
  • Converts unipolar control into symmetrical bipolar control
  • Supports forward and reverse control with one analogue signal
  • Nominal control range of −5 V to +5 V
  • Approximately ±20 mV neutral dead zone
  • Provides a −5 V auxiliary output for potentiometer control
  • Supports symmetrical centre-position potentiometer operation
  • High 1 MΩ control-input impedance
  • Designed for controllers equipped with an EM-A1 option-card socket

Overview

EM-A1 is a compact auxiliary circuit board that enables symmetrical positive and negative analogue control on compatible Electromen motor controllers. It allows motor speed and direction to be controlled with a single bipolar command signal.

The nominal control range is −5 V to +5 V, with zero volts representing the neutral or stop position. Positive and negative control voltages select opposite motor directions, while the magnitude of the voltage determines the requested control level.

Read more Show less

Bipolar Analogue Control

The EM-A1 converts a symmetrical analogue command into the unipolar speed and direction signals required by the compatible host controller. This enables forward and reverse operation from a single centre-referenced control signal.

The nominal full-scale input range is −5 V to +5 V. A dead zone of approximately ±20 mV around zero prevents small offset voltages or signal noise from unintentionally starting the motor.

Potentiometer Control

The option card can provide a −5 V auxiliary supply for a centre-position potentiometer. Together with the positive reference available from the host controller, this allows the potentiometer to generate a symmetrical negative-to-positive control voltage.

When the EM-A1 is installed, the −5 V supply is typically made available through the direction-input terminal of the host controller. The exact terminal assignment must be confirmed from the documentation for the applicable controller.

Extended Control Ranges

Some compatible Electromen controllers provide input attenuation that may allow wider external control ranges, such as ±10 V or ±30 V. The host controller’s input-scale adjustment is then used to match the external command range to the EM-A1 control circuitry.

The permissible voltage range and adjustment procedure depend on the host controller. Compatibility and scaling must therefore be confirmed before applying more than ±5 V to the control system.

Installation

The EM-A1 must only be installed in compatible Electromen products equipped with the dedicated EM-A1 option-card socket. The host controller should be disconnected from its power source before the option card is installed or removed.


Technical Data EM-A1

Function Unipolar-to-bipolar control conversion
Supply voltage 5–6 VDC
Current consumption Maximum 10 mA
Control-input impedance 1 MΩ
Nominal input range −5 V … 0 V … +5 V
Neutral dead zone Approximately ±20 mV
Negative auxiliary output −5 V
Maximum negative-output current 5 mA
Installation Dedicated EM-A1 option-card socket
Compatible products Electromen controllers equipped with an EM-A1 option-card socket
Operating temperature −40 … +70 °C

Product files

EN_em-A1.pdf (22.57 KB)
Stock: 50+ pcs.
8,00 €
VAT 0%

Ordering larger quantities +100pcs.

For volume discounts pls. see the Contact Info for Electromen distributors. If you didn´t find your country distributor then ask direct offer from office@electromen.com

AAA - credit rating

ISO-certified suppliers and subcontractors

100% Finnish production chain

Device design, programming, and laboratory testing

Short delivery time

Back to top