EM-A41 Supply Reduce and Emergency Relay

Key Features

  • Power-input front-end card for compatible DC motor controllers
  • Reduces standby current by disconnecting the main load in sleep mode
  • Pre-charge circuit for capacitive electronic loads
  • Reduces power-up inrush current through the main relay contacts
  • Hardware-controlled emergency shutdown with highest internal priority
  • Relay-monitoring circuit for detecting a potentially stuck relay
  • Automatic wake-up from FW or BW command inputs
  • Automatic sleep mode 30 seconds after the last active command
  • 30 A maximum continuous current at ambient temperatures below 50 °C
  • 40 A peak-current capability for 10 seconds

Overview

EM-A41 is a power-input front-end card for DC motor controllers and other compatible electronic loads. It is designed for applications requiring low standby current, controlled power switching and a hardware-based emergency shutdown input.

A built-in pre-charge circuit limits the charging current of capacitive loads before the main relay closes. This reduces the current surge at power-up and helps protect the main relay contacts from excessive inrush current.

Read more Show less

Pre-Charge Function

Many motor controllers and other electronic devices have large input capacitors. Connecting an uncharged capacitor bank directly to a power source can cause a very high momentary current that damages or shortens the service life of mechanical relay contacts.

The EM-A41 initially charges the connected capacitance through a controlled pre-charge path. The main relay is switched on after the pre-charge phase, reducing the current surge through the relay contacts and the upstream power switch.

Wake-Up and Sleep Operation

The card is activated by a voltage applied to either the FW or BW wake-up line. An active level of 4–35 V wakes the system and enables the main power path.

When neither wake-up command remains active, the EM-A41 returns to sleep mode after approximately 30 seconds. The specified sleep-mode current is 0.7 mA.

Emergency Shutdown

The emergency-shutdown function is implemented using a hardware circuit and has the highest internal control priority. The specified emergency-switch arrangement uses a normally closed contact.

Opening the emergency circuit causes the EM-A41 to disconnect the controlled power path. The complete machine-level emergency-stop function must nevertheless be designed and validated according to the safety requirements of the final application.

Relay Monitoring

The EM-A41 monitors the operation of its main relay. If the relay does not follow the commanded state, for example because its contacts remain stuck, the monitoring circuit can indicate a fault through the NPN fault output.

Power Capability

The card supports a maximum continuous load current of 30 A at ambient temperatures below 50 °C and a maximum peak current of 40 A for 10 seconds. The specified voltage drop is approximately 0.2 V at 30 A.


Technical Data EM-A41

Function Power-input front end with pre-charge, sleep and emergency-shutdown functions
Supply voltage 10–35 VDC
Maximum continuous current 30 A at Ta < 50 °C
Maximum peak current 40 A for 10 s
Voltage drop 0.2 V at 30 A
Calculated power loss at 30 A Approximately 6 W
Sleep-mode current 0.7 mA
Switch-on time 50 ms
Switch-off time 5 ms
Automatic sleep delay 30 s after the last active command
Wake-up inputs FW and BW
Wake-up voltage 4–35 V
Wake-up input impedance 47 kΩ
Recommended emergency switch Normally closed contact, minimum rating 1 A
Fault output NPN, maximum 30 V / 50 mA
Supply connectors Maximum conductor size 6 mm²
Control connectors Maximum conductor size 1.5 mm²
Operating temperature (Ta) −40 … +60 °C
EMC EN 50081-2 and EN 50082-2, industrial environment
Weight 55 g

Tuotetiedostot

EN_em-A41.pdf (34,60 KB)
Varastosaldo: 0 kpl
31,00 €
VAT 0%

Ordering larger quantities +100pcs.

For volume discounts pls. see the Contact Info for Electromen distributors. If you didn´t find your country distributor then ask direct offer from office@electromen.com

AAA - credit rating

ISO-certified suppliers and subcontractors

100% Finnish production chain

Device design, programming, and laboratory testing

Short delivery time

Takaisin ylös
Sivustomme käyttää evästeitä käyttäjäkokemuksen parantamiseksi. Voit muuttaa eväste valintojasi asetuksista
1 Tuotetta ostoskorissa
Ostoskori
Yhteensä:
0,00€