EM-M14 is an easy way to isolate current loop signals obtaining a good accuracy. No additional supply voltage is required. Voltage drop is minimal although the input voltage range is very wide. EM-M14 isolator is effectively protected against misconnections, over voltages and over currents. Output current can also be converted to a voltage signal with the inbuilt 100 ohm resistor. NOTE: As an additional feature the EM-M14 module can also be used to isolate loop powered transducers.
| TECHNICAL DATA | |
|---|---|
| Operating Range | 4...20 mA (0...25 mA) |
| Voltage Drop | 1:1 |
| Linearity Error | < 0.1 % |
| Thermal Drift | < 50 ppm/°C |
| Loading Error | < -0.05 % / 100 Ω |
| Load (RL) | 0...500 Ω |
| Input Voltage Range | 3...27 V |
| Input Voltage Limit | < 4 V when I = 20 mA |
| Over Current Limit | 30 V |